Furuno 1623 Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Senzory Furuno 1623. Furuno 1623 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 48
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
MARINE RADAR
MODEL 1623
OPERATOR'S MANUAL
www.furuno.co.jp
MODEL
Back
Zobrazit stránku 0
1 2 3 4 5 6 ... 47 48

Shrnutí obsahu

Strany 1 - MODEL 1623

MARINE RADARMODEL 1623OPERATOR'S MANUALwww.furuno.co.jpMODELBack

Strany 2

1. OPERATION 2 1.2 Indications TRAILG(IN)ES HIR HFTCEBLVRM45.0°1.25 nmRNG 0.62nmBRG 283.2°TTG 0H7M0.51.5nmZOOMRangeRange ring intervalZoomEcho trails

Strany 3 - IMPORTANT NOTICES

1. OPERATION 31.3 Turning Power On/Off Press the [POWER/BRILL] key to turn on the power. The unit beeps, the startup screen appears, and then the eq

Strany 4 - SAFETY INSTRUCTIONS

1. OPERATION 41.5 Adjusting Display Contrast, Brilliance 1. Press the [POWER/BRILL] key momentarily to show the brilliance/contrast adjustment wind

Strany 5 - TABLE OF CONTENTS

1. OPERATION 5 2. Press ▲ or ▼ to choose AUTO or MANU as appropriate. Automatic gain adjustment a) Press ► to open the automatic gain options window.

Strany 6 - Features

1. OPERATION 6 Manual A/C SEA adjustment While observing the screen and the A/C SEA tuning bar, press ◄ or ► to set the A/C SEA. The setting range is

Strany 7 - SYSTEM CONFIGURATION

1. OPERATION 7 6.0nm2.0 TargetVRMVRMrangeRange, bearingand time-to-goto cursor locationRNG 2.22nmBRG 45.62°TTG 02H21MCursorEBL - - - .-°VRM 2.91nm H

Strany 8 - EQUIPMENT LISTS

1. OPERATION 8Select where to shift Shifted displaywith the cursor.ChoosemanualSHIFTmode. How the manual shift works To cancel the

Strany 9 - 1.1 Controls

1. OPERATION 93. Press ► to show the options window for the item selected. For example, the illustration below shows the interference rejector option

Strany 10 - 1.2 Indications

1. OPERATION 102. Press ▲ or ▼ to choose INT REJECTION from page 1. 3. Press ► to open the options window. 4. Press ▲ or ▼ to choose OFF, LOW, MEDIUM

Strany 11 - 1.4 Transmitting, Standby

1. OPERATION 11 1.20 Guard Alarm The guard alarm allows the operator to set the desired range and bearing for a guard zone. When ships, islands, land

Strany 13 - 1.8 Suppressing Sea Clutter

1. OPERATION 121.21 Watchman Watchman transmits the radar for one minute to check if a target has entered or exited the guard zone from the previous

Strany 14 - 1.10 Measuring the Range

1. OPERATION 131.23 PROG Key The [PROG] key acts as a menu shortcut key. You may use any User menu item except “SYSTEM MENU.” Using the PROG key 1

Strany 15 - 1.12 Shifting the Display

1. OPERATION 141.25 Turning Navigation Data On/Off Navigation data appears on the bottom half of the screen as in the illustration below. You may tur

Strany 16 - 1.14 User Menu Overview

1. OPERATION 15GRAPHIC DISPLAYS DIGITAL DISPLAYS1 0.5 0 0.5 1Waypoint 03Rng 0.19n

Strany 17 - 1.16 Interference Rejector

1. OPERATION 161.27 System Menu The System menu mainly contains items which once set do not require frequent adjustment. You may display this menu by

Strany 18 - 1.19 Echo Stretch

1. OPERATION 17 PANEL DIMMER: You may adjust panel backlighting from among OFF, LOW, MEDIUM and HIGH. HUE: The default hue setting (DAY) display is

Strany 19 - 1.20 Guard Alarm

182. MAINTENANCE, TROUBLESHOOTINGWARNINGELECTRICAL SHOCK HAZARDDo not open the equipment.Only qualified personnelshould work inside theequipment.NOT

Strany 20 - Rain Clutter

2. MAINTENANCE, TROUBLESHOOTING 192.2 Replacing the Fuse The fuse (5 A) in the power cable protects the equipment against reverse polarity of ship’s

Strany 21 - 1.23 PROG Key

2. MAINTENANCE, TROUBLESHOOTING 202.4 Diagnostics If you feel that your unit is not working properly, conduct the appropriate diagnostic test, displa

Strany 22 - Displays

2. MAINTENANCE, TROUBLESHOOTING 21ANTENNA STATUS : OK(47)#HEADING : OKBEARING : OK (24.0rpm)*TUNE :TOTAL ON TI

Strany 23 - 14:25:03

iNi-Cd PbIMPORTANT NOTICES General • The operator of this equipment must read and follow the descriptions in this manual. Wrong operation or mainte

Strany 24 - 1.27 System Menu

223. INSTALLATION3.1 Antenna Unit Installation Mounting considerations When selecting a mounting location for the antenna unit keep in mind the fol

Strany 25 - 1. OPERATION

3. INSTALLATION 233. Using the hexagon head bolts, flat washers and spring washers removed at step 1, fasten the antenna unit to the platform. The t

Strany 26 - 2.1 Maintenance

3. INSTALLATION 247. Referring to the figure below, fasten the shield cable with a screw (M4x10) on the chassis to ground the unit. Connect 9 pin

Strany 27 - 2.2 Replacing the Fuse

3. INSTALLATION 25Mounting plateSupport plate (1)Support plate (2)Bracket (1)Bracket (2)Fixing plateM8 x 20M8 x 20(A) Assembling the mounting bracket

Strany 28 - 2.4 Diagnostics

3. INSTALLATION 263.3 Wiring Connect the antenna cable, the power cable and the ground wire as shown below. FUSE (5 A)12-24 VDCPOWER CABLEDISPLAY UNI

Strany 29 - 2.5 Test Pattern

3. INSTALLATION 27 Display unit, rear view 3. Close the rear panel, making sure the gasket is correctly positioned. 4. Plug in the connector of th

Strany 30 - Mounting considerations

3. INSTALLATION 28 8. Press ▲ to select YES, and the display now looks as below. HEADING LINE ADJUSTMENT BY’ ’ AND ’ ’ KEYS.THEN PUSH MODE KEY TO

Strany 31

3. INSTALLATION 29NMEA port setup, GPS WAAS setup The NMEA port can function as an input port or input/output port. If you are using the GP-320B, tu

Strany 32 - Antenna base

MN-1MENU TREE MENU/ESC key+POWER/BRILLkeySIMULATION (OFF, ON, HIGH) TEST (Tests display unit.)LCD PATTERN (Displays test pattern.)MEMORY CLEAR (Rest

Strany 33

This page is intentionally left blank.

Strany 34 - 3.3 Wiring

iiSAFETY INSTRUCTIONSSafety Instructions for the OperatorWARNINGELECTRICAL SHOCK HAZARDDo not open the equipment.Only qualified personnelshould work

Strany 35 - 3.4 Adjustments

SP - 1 E3510S01F SPECIFICATIONS OF MARINE RADAR MODEL 1623 1 GENERAL 1.1 Indication System PPI Daylight display, raster scan, 4 tones in monoch

Strany 36 - Timing adjustment

SP - 2 E3510S01F 4.3 Range, Range Interval, Number of Rings Range (nm/km) 0.125 0.25 0.5 0.75 1 1.5 2 3 4 6 8 12 16 24Ring Interval 0.

Strany 37

PACKING LIST03GJ-X-9851 -15MODEL1623-J-0/10/15/20,MODEL1623-E-0/10/15/20N A M EO U T L I N EDESCRIPTION/CODE №Q'TY1/1ユニット UNIT空中線部ANTENNA UNITRSB

Strany 38 - MENU TREE

Oct. 2, '02D - 1

Strany 39

Oct. 2, '02D - 2

Strany 40

Y. HataiD - 3

Strany 41

2431ABCMASSkgDRAWNCHECKEDAPPROVEDSCALENAME名称TITLE相互結線図MARINE RADARINTERCONNECTION DIAGRAM船舶用レーダーMODEL 162303-160-6001-0DWG.No. REF.No.15/Feb/2011T.YAM

Strany 43 - Oct. 2, '02

The paper used in this manualis elemental chlorine free.・FURUNO Authorized Distributor/Dealer9-52 Ashihara-cho,Nishinomiya, 662-8580, JAPANTelephone :

Strany 44

iiiTABLE OF CONTENTS FOREWORD... iv SYSTEM CONFIGURATION... v EQUIPMENT LISTS...

Strany 45 - Y. Hatai

ivFOREWORD A Word to the Owner of the MODEL 1623 Congratulations on your choice of the FURUNO MODEL 1623 Marine Radar. For over 60 years FURUNO Ele

Strany 46 - 16/Feb/2011 Y.NISHIYAMA

vSYSTEM CONFIGURATION DISPLAYUNITRDP-141EXTERNALBUZZERXH3-BZ-L97012-24 VDCRECTIFIERPR-62: Standard supply: Optional supply: Local supply100/110/220/

Strany 47

viEQUIPMENT LISTS Standard supply Name Type Code No. Qty Remarks Antenna Unit RSB-0093 — 1 Display Unit RDP-141 — 1 CP03-25301 008-442-2

Strany 48 - (YOSH ) MODEL1623

1 1. OPERATION 1.1 Controls Display unit How to remove the hard cover Place your thumbs at the center of the cover, and then lift the cover while p