Furuno FCV-30 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro GPS přijímač Furuno FCV-30. Furuno FCV-30 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 110
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - COLOR SOUNDER

COLOR SOUNDERFCV-30Back

Strany 2 - FCV-30FCV-30

viii This page intentionally left blank.

Strany 3 - IMPORTANT NOTICES

APPENDIX AP-4 7 8Color Day/Night (Day, Night) Hue (Standard, Mono, USER1, USER2)

Strany 4 - SAFETY INSTRUCTIONS

APPENDIX AP-5ETRFile Load user setting (1-3)Save user setting (1-3)CloseDisp Mode Display mode (HF single, LF single, Dual freq, HF zoom, LF zoom)Zoo

Strany 5

APPENDIX AP-6 System TX/RX Low/High freq. Gain adjustment (-50-50; 0)Freq adjustment (-10.0-10.0; 0)TX power reduction (OFF, ON)TX pulse length (Shor

Strany 6 - TABLE OF CONTENTS

APPENDIX AP-7Screen Division A-scope display ON PIC1PIC1PIC2PIC3 PIC2 PIC1PIC2PIC1AAAAPIC1PIC2PIC3PIC4PIC5PIC3PIC1PIC2PIC1PIC1Division: Left, Right D

Strany 7

APPENDIX AP-8 A- scope display OFF PIC2PIC3PIC1PIC1PIC1PIC2PIC2PIC1PIC1PIC3PIC2PIC1PIC2PIC3PIC4PIC4PIC3PIC2PIC1PIC4PIC3PIC2PIC1PIC5PIC1PIC2PIC3PIC4PI

Strany 8 - FOREWORD

FURUNO FCV-30 SP - 1 E2373S01E 060414 SPECIFICATIONS OF THE COLOR VIDEO SOUNDER FCV-30 1. DISPLAY 1.1 Display Optional supply or commercial mon

Strany 9 - SYSTEM CONFIGURATION

FURUNO FCV-30 SP - 2 E2373S01E 060414 5. ENVIRONMENTAL CONDITION 5.1 Useable Temperature Range Processor Unit 0°C to +40°C Transducer -5°C to +3

Strany 10

IN-1INDEX A Alarms audio volume ...

Strany 11 - 1. OPERATIONAL OVERVIEW

INDEX IN-2 T Target graph window ... 2-8 Temperature alarm ... 1-28 Three-beam display...

Strany 12 - 1.2 Menu Operation

Furuno Electric Co., Ltd. Terms (EULA) • You have acquired a device (“DEVICE”) that includes software licensed by Furuno Electric Co., Ltd from an

Strany 13 - Enabled Disabled

1-11. OPERATIONAL OVERVIEW 1.1 Controls F1F3F4F2Turns the poweron/off.User-programmablefunction keys.Left buttonConfirms menu selection.Right button

Strany 14 - Bottom alarm

 Internet-Based Services Components. The SOFTWARE may contain components that enable and facilitate the use of certain Internet-based services. Yo

Strany 15

1. OPERATIONAL OVERVIEW 1-2 1.2 Menu Operation The FCV-30 is controlled from a menu system. Two types of menus are available: Main menu: All menu o

Strany 16

1. OPERATIONAL OVERVIEW 1-33. Change settings as appropriate, referring to the information below. 4. After changing settings, roll the trackball to

Strany 17 - 1.4 Transmitting, Receiving

1. OPERATIONAL OVERVIEW 1-4 TenkeyClose Tenkey panel Place the cursor on the desired numeric key and then push the left button. Repeat to enter all d

Strany 18 - 1.5 Displays

1. OPERATIONAL OVERVIEW 1-51.2.2 How to use the pop-up menus 1. Right-click anywhere on the screen, and a pop-up menu appears. Indicates an option

Strany 19 - 1.5.2 Split-beam display

1. OPERATIONAL OVERVIEW 1-6 1.3 Turning the Power On/Off Turning on the power 1. Turn on the monitor. 2. Open the power switch cover on the Contro

Strany 20 - 1.5.3 Three-beam display

1. OPERATIONAL OVERVIEW 1-71.4 Transmitting, Receiving Follow the procedure below to start transmitting and receiving, after turning on the power. 1

Strany 21 - Simul. TX

1. OPERATIONAL OVERVIEW 1-8 1.5 Displays 1.5.1 Choosing a display Six display modes are available. Choose the display mode which matches your current

Strany 22 - Deep mode, Simul. TX

1. OPERATIONAL OVERVIEW 1-91.5.2 Split-beam display The split-beam display shows the underwater images captured with the split-beam. With display of

Strany 23 - 1 2 3 4 5 6 7 8 9 10 11 12

The paper used in this manualis elemental chlorine free.FURUNO Authorized Distributor/DealerFURUNO Authorized Distributor/Dealer9-52 Ashihara-cho,9-52

Strany 24

1. OPERATIONAL OVERVIEW 1-10 1.5.3 Three-beam display The three-beam display shows the images captured from the port, downward and starboard directio

Strany 25 - Shift the start

1. OPERATIONAL OVERVIEW 1-11Note: Normally, pulses are fired from beam 1, beam 2 and beam 3 in that order and displayed on the screen as the port, d

Strany 26 - 1.8 Adjusting the Gain

1. OPERATIONAL OVERVIEW 1-12 Deep mode, Simul. TX Menu bar 1.5.5 User 1, User 2, User 3 display These displays show the product of displays created

Strany 27

1. OPERATIONAL OVERVIEW 1-131.6 Choosing a Display Range Choose the detection range (from the transducer to the bottom), in 12 preset choices. The d

Strany 28 - 1.11 Fish Size Histogram

1. OPERATIONAL OVERVIEW 1-14 3. Click ▼ in the Range box. Range options 4. Click the range you wish to use. For example, choosing “80”, the display

Strany 29

1. OPERATIONAL OVERVIEW 1-151.7 Shifting the Display Range You may shift the display in order to look at a shallower or deeper depth without changin

Strany 30 - 1.12 Setting Measuring Area

1. OPERATIONAL OVERVIEW 1-16 1.8 Adjusting the Gain Adjust the gain according to signal strength. Adjust so noise just disappears from the screen.

Strany 31 - 1.12.4 Measuring bottom fish

1. OPERATIONAL OVERVIEW 1-171.9 Find Depth and Position of a Fish Echo You may measure the depth to a fish school or bottom with the horizontal line

Strany 32

1. OPERATIONAL OVERVIEW 1-18 1.10 Inscribing Lines You may inscribe vertical lines on the display to mark fish schools, shoals, etc. When an echo of

Strany 33 - (Clutter suppression)

1. OPERATIONAL OVERVIEW 1-19Area of measurement Number of fish within measuring areaVert. axis Number of fish within vertical axis2040608004000:00:

Strany 34 - 1.14 Eliminating Weak Echoes

iIMPORTANT NOTICES • No part of this manual may be copied or reproduced without written permission. • If this manual is lost or worn, contact your

Strany 35 - 1.16 Picture Advance Speed

1. OPERATIONAL OVERVIEW 1-20 1.12 Setting Measuring Area There are four ways to set the measurement area for the fish size histogram: • Measure fish

Strany 36

1. OPERATIONAL OVERVIEW 1-215. Click ◄ or ► in the Area Vertical box to set the vertical width of the area marker. (Setting range: 10-100(%)). Repres

Strany 37 - 1.17 A-scope Display

1. OPERATIONAL OVERVIEW 1-22 40Measurement range marker(2)ashed yellow vertical line)204060800Measurement range marker(1)(Short yellow horizontal das

Strany 38 - 1.18 Alarms

1. OPERATIONAL OVERVIEW 1-231.13 Suppressing Low Level Noise (Clutter suppression) Light-blue dots may appear over most of screen. This is mainly du

Strany 39

1. OPERATIONAL OVERVIEW 1-24 1.14 Eliminating Weak Echoes Sedimented water or reflections from plankton may be painted on the display in green or lig

Strany 40

1. OPERATIONAL OVERVIEW 1-251.16 Picture Advance Speed The picture advance speed determines how quickly the vertical scan lines run across the screen

Strany 41 - 1.19 Function Keys

1. OPERATIONAL OVERVIEW 1-26 Ship’s speed dependent picture advance With speed data provided by a speed-measuring device, picture advance speed may b

Strany 42 - Scroll bar

1. OPERATIONAL OVERVIEW 1-271.17 A-scope Display The A-scope display shows echoes at least at each transmission with amplitudes and tone proportional

Strany 43 - 1.20.2 Loading user settings

1. OPERATIONAL OVERVIEW 1-28 1.18 Alarms This sounder has four alarms: bottom alarm, bottom fish alarm, water temperature alarm and vertical temper

Strany 44

1. OPERATIONAL OVERVIEW 1-291.18.2 Enabling, disabling an alarm 1. Click Settings. 2. Click Alarm. Alarm dialog box 3. Check the box in Bottom al

Strany 45

ii SAFETY INSTRUCTIONSWARNINGELECTRICAL SHOCK HAZARDDo not open the equipment.Only qualified personnelshould work inside theequipment.Immediately tu

Strany 46 - Volume (E):

1. OPERATIONAL OVERVIEW 1-30 7. Click the OK button. 2040608005000:00:28 34 42.616' N135 19.740' EAlarm markerAlarm rangeStarting pointGr

Strany 47 - 1.21.2 Recording data

1. OPERATIONAL OVERVIEW 1-311.19 Function Keys The function keys on the control unit provide for one-touch access to the setting window of your choic

Strany 48

1. OPERATIONAL OVERVIEW 1-32 1.20 Saving, Recalling User Settings You may save echo sounder settings, and recall them when desired. This is useful w

Strany 49 - File location box

1. OPERATIONAL OVERVIEW 1-331.20.2 Loading user settings Note that you cannot load user settings while transmitting. 1. Click File. 2. Click Load

Strany 50 - Check to

1. OPERATIONAL OVERVIEW 1-34 Note: You may use the Details button to display detailed information about the chosen display settings. This windowshows

Strany 51 - Extension

1. OPERATIONAL OVERVIEW 1-351.21 Recording, Replaying Data The USB port on the processor unit connects to a USB 2.0 hard disk (user supplied) to rec

Strany 52 - 2006_04_10

1. OPERATIONAL OVERVIEW 1-36 4. Click the Reference button. Volume (E): 5. Choose location of data recording and then close the Reference window.

Strany 53

1. OPERATIONAL OVERVIEW 1-371.21.2 Recording data 1. Connect a USB hard disk to the USB port on the processor unit. 3. Click File. File menu 3. Cli

Strany 54

1. OPERATIONAL OVERVIEW 1-38 1.21.3 Converting recorded data to HAC format Recorded data can be converted to HAC format data, the standard archiving

Strany 55 - 2. WINDOW DISPLAYS

1. OPERATIONAL OVERVIEW 1-399. With the slider bars, choose start position and end position. 10. Click the Start button to start the conversion. The

Strany 56 - Window currently

iiiCAUTIONDo not transmit when the transducer isout of water.The transducer may become damaged.The picture does not advance when thepicture advance

Strany 57 - 2.2.1 Status window

1. OPERATIONAL OVERVIEW 1-40 11. Click the Open button to start playback. Sliding barCheck torepeatplayback. Play dialog box Notes on playing back

Strany 58

1. OPERATIONAL OVERVIEW 1-411.21.5 Saving screen shot You may take a screen shot to save the current window. Compared to raw data, the size of the sc

Strany 59 - Data display description

1. OPERATIONAL OVERVIEW 1-42 1.21.6 Loading a screen shot 1. Connect hard drive to the USB on the processor unit. 2. Click File. 3. Click Load the

Strany 60

1. OPERATIONAL OVERVIEW 1-43 11. To erase the screen shot. click the Close button.

Strany 61

1. OPERATIONAL OVERVIEW 1-44 This page intentionally left blank.

Strany 62 - 2.2.3 Target graph window

2-12. WINDOW DISPLAYS The FCV-30 has eight window displays: status, fish size histogram, target graph, V-temp graph, bottom zoom, bottom lock, marke

Strany 63

2. WINDOW DISPLAYS 2-2 Automatically arranging windows 1. Click Window on the menu bar. Window currentlydisplayed. (Clickto bring windowto front.) 2

Strany 64

2. WINDOW DISPLAYS 2-32.2 Interpreting the Window Displays 2.2.1 Status window The Status window shows current settings and data input from external

Strany 65

2. WINDOW DISPLAYS 2-4 This window shows which indications are currently displayed. Status dialog box 3. Click items in the Display Item window as a

Strany 66 - 135 19.740' E

2. WINDOW DISPLAYS 2-5Data display description Item Description Picture advance Show current picture advance setting. Shift Show current shift value

Strany 67

iv TABLE OF CONTENTS FOREWORD ... vi SYSTEM CON

Strany 68

2. WINDOW DISPLAYS 2-6 2.2.2 Fish size histogram window The fish size histogram shows fish size within the selected measuring area. The SPLIT (split

Strany 69 - 3. CHANGING SETTINGS

2. WINDOW DISPLAYS 2-7Note: If the Target graph dialog box appears, click the Fish size histogram tab. Description of Fish size dialog box Menu item

Strany 70

2. WINDOW DISPLAYS 2-8 2.2.3 Target graph window The target graph window plots fish echo position (latest three scans). It is available when the SPL

Strany 71 - 3.2 Display Item Dialog Box

2. WINDOW DISPLAYS 2-9 Fish size dialog box, Display tab Note 1: If the Measurement or Unit dialog box appears, click the Display tab to open the Dis

Strany 72 - 3.3 Echo Image Dialog Box

2. WINDOW DISPLAYS 2-10 2.2.4 V-temperature graph window The V-temperature graph window plots depth and water temperature data fed from a net sonde o

Strany 73

2. WINDOW DISPLAYS 2-11Setting up the v-temp graph 1. Click System. 2. Click Net. Input data: Choose the format of data fed from net sonde or trawl

Strany 74 - 3.4 Multi beam Dialog Box

2. WINDOW DISPLAYS 2-12 Setting bottom lock zoom range 1. Click Setting. 2. Click Echo image. 3. Click ▼ in the Zoom range box and push the left but

Strany 75 - 3.5 Temp Dialog Box

2. WINDOW DISPLAYS 2-132.2.7 Marker zoom window The marker zoom window zooms echoes within the expansion marker (blue dashed line). This marker is o

Strany 76 - 3.6 Color Dialog Box

2. WINDOW DISPLAYS 2-14 2.2.8 Bottom discrimination graph window The bottom discrimination graph plots bottom nature, and it can be plotted on the b

Strany 77

3-13. CHANGING SETTINGS This chapter provides the information necessary for changing equipment settings. For details about specific dialog boxes, se

Strany 78 - 3.7 Unit Dialog Box

v1.21.3 Converting recorded data to HAC format... 1-38 1.21.4 Playing back data ...

Strany 79

3. CHANGING SETTINGS 3-2 4. Click the Display mode change button. Shows direction of detection beam. Display mode change dialog box 5. In the Displ

Strany 80

3. CHANGING SETTINGS 3-33.2 Display Item Dialog Box The Display Item dialog box lets you choose what indications to display. 1. Click Disp. 2. Clic

Strany 81 - 3.9 External Echo Sounder

3. CHANGING SETTINGS 3-4 Temp graph scale: Choose where to display the temperature graph scale: Left, Left-Mid, Center, Right-Mid, Right. Bottom dis

Strany 82 - 3.9.2 File menu

3. CHANGING SETTINGS 3-5User ranges If the factory-prepared display ranges or zoom ranges are not to your liking, you may use your own ranges, by fol

Strany 83 - 3.9.3 Display menu

3. CHANGING SETTINGS 3-6 Color resolution: Effective when “Clutter curve” is turned off. You may set display width dB for colors. Set display width d

Strany 84

3. CHANGING SETTINGS 3-7Depth/Distance: This function compensates for depth difference between the picture from the downward beam and other that from

Strany 85 - 3.9.4 Setting menu

3. CHANGING SETTINGS 3-8 3.6 Color Dialog Box The Color dialog box lets you set the colors to use. 1. Click System. 2. Click Color. Color dialog b

Strany 86

3. CHANGING SETTINGS 3-9Basic colors:Custom colorsDefine Custom Colors >>OK CancelColor Standard color choices 3. Choose a color

Strany 87 - 3.9.5 System menu

3. CHANGING SETTINGS 3-10 Temp graph: Choose the color of the graph line in temperature graph. Bottom discrimination: Choose the color of the graph

Strany 88

3. CHANGING SETTINGS 3-113.8 Target Sphere Calibration Dialog Box To accurately analyze fish distribution, it is necessary to calibrate target stren

Strany 89

vi FOREWORD Introduction FURUNO Electric Company thanks you for considering and purchasing the FCV-30 Color Sounder. We are confident you will disco

Strany 90 - 0252310-XX.XX

3. CHANGING SETTINGS 3-12 8. Click Target sphere calibration. 9. In the Target sphere TS box, use ◄ or ► to set the TS value (fixed value) of the

Strany 91 - 4.1 Maintenance

3. CHANGING SETTINGS 3-133.9 External Echo Sounder This equipment can show the image from the FURUNO echo sounder ETR-30N. 3.9.1 Displaying image

Strany 92 - Use the proper fuse

3. CHANGING SETTINGS 3-14 3.9.2 File menu Click File on the external echo sounder window’s menu bar. Load user setting: Recall saved user settings.

Strany 93 - Trackball

3. CHANGING SETTINGS 3-153.9.3 Display menu Click Display on the external echo sounder window’s menu bar. ETR setting window Display mode: Choose d

Strany 94 - 4.2 Troubleshooting

3. CHANGING SETTINGS 3-16 ETR display item dialog box Show or hide Color bar, Time marker, Mode indicator, V-VRM, H-VRM and Depth indication. Displa

Strany 95

3. CHANGING SETTINGS 3-173.9.4 Setting menu 1. Click Setting on the echo sounder window’s menu bar. 2. Click Echo image. Range: Choose display ran

Strany 96 - X = Board version no

3. CHANGING SETTINGS 3-18 STC: Help distinguish surface fish from surface echoes. The setting range is 0-10; the higher the setting the greater the e

Strany 97

3. CHANGING SETTINGS 3-193.9.5 System menu 1. Click Setting on the menu bar 2. Click System. ETR TX/RX dialog box Click TX/RX on the System menu to

Strany 98

3. CHANGING SETTINGS 3-20 Tx pulse length (Manual): Operative when TX pulse length is set to Manual. The pulse length range is 0.2-5(ms). The smaller

Strany 99

3. CHANGING SETTINGS 3-21ETR Color dialog box Day/Night: Choose background color of the echo sounder window. Choose “Day” for white background; “Nig

Strany 100 - APPENDIX

viiSYSTEM CONFIGURATION POWERF1F4F3F2Processor UnitCV-300Control UnitCV-301100-240 VAC1φ, 50/60 Hz100-120/200-240 VAC1φ, 50/60 HzTransceiver UnitCV-

Strany 101

3. CHANGING SETTINGS 3-22 Unit menu Choose unit of depth measurement. Test/Initialization menu Simulation: The simulation mode provides simulated e

Strany 102

4-14. MAINTENANCE & TROUBLESHOOTING 4.1 Maintenance Regular maintenance is important for maintaining good performance. Follow the recommended pr

Strany 103 - Screen Division

4. MAINTENANCE & TROUBLESHOOTING 4-2 4.1.3 Replacing fuses Fuses protect the processor unit and transceiver unit from overvoltage and internal f

Strany 104 - A- scope display OFF

4. MAINTENANCE & TROUBLESHOOTING 4-34.1.5 Trackball If the trackball does not roll smoothly it may require cleaning. Do the following to clean th

Strany 105 - 4. POWER SUPPLY

4. MAINTENANCE & TROUBLESHOOTING 4-4 4.2 Troubleshooting The section provides information which the user can follow to restore normal operation.

Strany 106 - 5. ENVIRONMENTAL CONDITION

4. MAINTENANCE & TROUBLESHOOTING 4-54.3 Restoring Default Settings You may wish to restore all default settings to start operation afresh or to

Strany 107

4. MAINTENANCE & TROUBLESHOOTING 4-6 4. Click the Yes button. Yes No 5. Click the Yes button to restore all default

Strany 108

AP-1APPENDIX Menu Tree Display Mode Display Mode (SPLIT, 3 BEAM, SPLIT + 2 BEAM USER 1, USER 2, USER 3)Display mode DIsplay Itemchange (SPLIT, BEAM1

Strany 109

APPENDIX AP-2 Zoom range (2m, 5m, 10m, 20m, 40m)User setting Range1 (2-200: 2m)Range2 (2-200: 5m)Range3 (2-200: 10m)Range4 (2-200: 20m)Range5 (2-200:

Strany 110

APPENDIX AP-3 Alarm Volume (0, 1, 2, 3, 4, 5, 6, 7)Bottom alarm Alarm depth (0-10000; 0m)Alarm zone (1-10000: 1m)Fish alarm Alarm

Komentáře k této Příručce